Type: Catheter
Material: Medical Grade PVC,TPU,PC
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 3 Years
Group: All
Logo Printing: With Logo Printing
Samples:
US$ 5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
OEM
Size
20/30cm
Supply Voltage
2-10VDC or VAC RMS
Frequency Response
1200 Hz
Light Sensitivity
1 Mmhg
Dielectric Breakdown
10000 VDC
Warm-up Time
5 Seconds
Transport Package
Blister/Carton
Specification
56*50*53 cm
Trademark
OEM
Origin
China
HS Code
9018390000
Production Capacity
10000PCS/Day

Product Description

Product Description
 
Disposable blood pressure transducer
Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years
Medical Disposable Single/Double Channel Blood Central Venous Pressure TransducerMedical Disposable Single/Double Channel Blood Central Venous Pressure Transducer
Production Line
Medical Disposable Single/Double Channel Blood Central Venous Pressure TransducerMedical Disposable Single/Double Channel Blood Central Venous Pressure TransducerMedical Disposable Single/Double Channel Blood Central Venous Pressure Transducer
Certificates
Medical Disposable Single/Double Channel Blood Central Venous Pressure TransducerMedical Disposable Single/Double Channel Blood Central Venous Pressure Transducer

Company Information
Medical Disposable Single/Double Channel Blood Central Venous Pressure TransducerMedical Disposable Single/Double Channel Blood Central Venous Pressure Transducer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now